ACO
Stormwater Drainage
Technical Support - Chemical Resistance Chart
About Us ACO Group of Companies
Local Sales Support
Home         
      1300 765 226 (AUS)   0800 448 080 (NZ)   + 61 2 4747 4000 (Export)   Contact ACO Online   


   
Polyester
 
Vinyl ester
Chemical Medium  
Max.
Conc
Short Term
Exposure
72 Hours
Long Term
Exposure
42 Days
Max.
Conc
Short Term Exposure
72 Hours
Long Term
Exposure
42 Days
Acetic Acid
Acetone
Ammonia
Aniline
Aniline in Ethyl Alcohol
Benzene
Boric Acid
Butyric Acid
Butyl Alcohol
Calcium Chloride
Calcium Hydroxide
Caster Oil
Chloric Acid
Chromic Acid
Citric Acid
Diesel Fuel
Ethanol
Ethlendiamine
Ethyl Acetate
Ferrous Sulfate
Fluorallic Acid
Formaldehyde
Formic Acid
Fuel Oil
n-Heptane
n-Hexane
Hydraulic Oil
Hydrochloric Acid
Hydrofluoric Acid
JP4
JP8
Lactic Acid
Methanol
Methyl Amine
Methyl Ethyl Ketone
Mineral Oil SAE5W50
Monochlor Benzene
Monochloroacetic Acid
Nitric Acid
n-Nonane
Iso-Octane
Oxalic Acid
Petrol
Phenol
Phosphoric Acid
Potassium Hydroxide
Sodium Acetate
Sodium Carbonate
Sodium Chloride
Sodium Hydroxide
Sodium Hypochloric
Sulfuric Acid
Tetrafluoroborsaure
Toluene
Trichloroethylene
Triethylamine
Xylene
 
30%
10%
10%
100%
10%
100%
100%
25%
100%
100%
100%
100%
5%
5%
100%
100%
100%
100%
100%
30%
10%
35%
10%
100%
100%
100%
100%
10%
5%
100%
100%
10%
5%
100%
100%
100%
0.05%
10%
10%
100%
100%
100%
100%
100%
10%
10%
100%
20%
100%
15%
5%
40%
20%
100%
100%
100%
100%
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y
Y

N
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y

N
N
N
N

Y
N
Y
Y
Y
Y

N
Y
N
Y
Y
Y

N
Y
N
Y
Y
Y

N
Y
Y
Y
Y
Y

N
Y
Y
Y

N
N
N

Y
N
Y
N
Y
N
Y
Y

N
Y
N
N

Y
Y

N
Y
Y

N
N
N

Y
N
 
75%
10%
10%
100%
10%
100%
100%
50%
100%
100%
100%
100%
5%
20%
100%
100%
95%
100%
100%
100%
10%
100%
10%
100%
100%
100%
100%
37%
20%
100%
100%
100%
5%
100%
100%
100%
0.05%
10%
20%
100%
100%
100%
100%
100%
75%
10%
100%
35%
100%
25%
5%
70%
20%
100%
100%
100%
100%
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y

Y
N
N
N

Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y
Y

N
N
N

Y
Y
Y
Y
Y
Y
Y
Y

N
Y
Y
Y
Y
Y
Y
Y
Y
Y

N
N

Y
N
Maximum operating temperature 82°C

Note:
• If ACO Drain standard products are unable to provide adequate chemical resistance, refer to ACO Stainless trough.
• These recommendations are for guidance only. Customers are advised to test a sample of polymer concrete to ensure
   suitability. Test samples are available free of charge from ACO

 

| Home |

© ACO AUSTRALIA 2019