‘Hydro’ is a purpose written, hydraulic design
program modelled on differential calculus for non-uniform flow in open channels. The program was further refined with
empirical data, following a series of
experiments modelling lateral intake into
trenches. Analysis of the effect of slope,
run length, and trench cross sectional
profiles were incorporated into the program.
Complex scenarios such as the effects of
water inflow from downpipes or inlets
along the length of the trench can also be
modelled by the ‘Hydro’ program. ACO can
use ‘Hydro’ to recommend optimum outlet
positions along trench runs.
To generate results from the ‘Hydro’ program, the following information is required:
|
Length of trench run (metres) |
|
Length and width of catchment area (metres) |
|
Surrounding pavement/surface type, e.g., concrete, asphalt, etc. |
|
Rainfall intensity (mm/hr) |
|
Ground fall along trench (%) |
|
Perpendicular approach slopes to trench (%) |
|
Preferred position of outlets along trench and any outlet size restrictions |
|
Any slab depth restrictions |
Results are provided either electronically (PDF) and/or in printout format.